What are the requirements for the grounding of the Shielded control cable

What are the requirements for the grounding of the Shielded control cable

  • Categories:Industry news
  • Author:
  • Origin:
  • Time of issue:2022-03-25 14:31
  • Views:

(Summary description)In the process of using the Shielded control cable, a key link is grounding. And it has some requirements for grounding. If the corresponding requirements are not met, it will bring a lot of inconvenience to the subsequent use.

icon icon icon icon

What are the requirements for the grounding of the Shielded control cable

(Summary description)In the process of using the Shielded control cable, a key link is grounding. And it has some requirements for grounding. If the corresponding requirements are not met, it will bring a lot of inconvenience to the subsequent use.

  • Categories:Industry news
  • Author:
  • Origin:
  • Time of issue:2022-03-25 14:31
  • Views:
Information

In the process of using the Shielded control cable, a key link is grounding. And it has some requirements for grounding. If the corresponding requirements are not met, it will bring a lot of inconvenience to the subsequent use. So, what are the requirements for the grounding of the Shielded control cable? The following Shielded control cable manufacturers will take you to learn more about it.

Best Shielded control cable Manufacturers china
1. The shielding layer of the analog signal loop control cable of the computer monitoring system should not constitute two or more grounding points, but should be concentrated on one grounding point.
2. The shielding layers of current, voltage and signal cables protected by integrated circuits and microcomputers should be grounded at the switch placement and the control room at the same time.
3. In addition to the above cases, when the electromagnetic induction interference is large, two-point grounding should be used; when the electrostatic induction interference is large, one-point grounding can be used. For double shielding or composite universal shielding, one point and two points should be used for inner and outer shielding, respectively.
4. For the choice of two-point grounding, the shielding layer should not burn out under the action of transient current.
Shielded control cable grounding requirements are introduced here, do you understand clearly? If you want to buy, you can contact our company at any time.